C. Cont. Mode
Press the and buttons to scroll the cursor to the sensor type. Press the
button to enter the black-mark sensor calibration mode.
C-1 Automatic
When you select the [Automatic] option, you will see the following message and the printer
will calibrate the sensor sensitivity automatically. When the calibration process is completed,
the LCD screen will return to the previous menu.
C-2 Manual
In case “Automatic” sensor calibration cannot apply to the media, please use the “Manual”
function to calibrate the sensor manually.
When you select the [Manual] option, you will see the following message. Please complete
these steps
Cont. Mode
Remove Label
Intensity x
Ref. Level xxx
1. Remove the continuous label. Press
the
button to set the value
into the printer.
Cont. Mode
Scan Paper
Intensity x
Ref. Level xxx
2. Then, put the continuous label under
the media sensor. Press the
button to set the value into
the printer.
Calibration 3/4
Bline Mode
> Cont. Mode
Exit
Cont. Mode 1/3
> Automatic
Manual
Exit
Cont. Mode
Automatic
Cont. Mode 2/3
Automatic
> Manual
Exit