B-4
Wasp WPS100 Product Reference Guide
The modifier character is the sum of the applicable option values based on Tabl e B-3.
Table B-3. Modifier Characters
Code Type Option Value Option
Code 39
0 No Check character.
1 Reader has checked one check character.
3 Reader has checked and stripped check character.
4 Reader has performed Full ASCII character conversion.
5 Reader has performed Full ASCII character conversion and
checked one check character.
7 Reader has performed Full ASCII character conversion and
checked and stripped check character.
Example: A Full ASCII bar code with check character W, A+I+MI+DW, is transmitted
as ]A7AimId where 7 = (3+4).
Trioptic Code 39
0 No option specified at this time. Always transmit 0.
Example: A Trioptic bar code 412356 is transmitted as ]X0412356
Code 128
0 Standard data packet, No Function code 1 in first symbol position.
1 Function code 1 in first symbol character position.
2 Function code 1 in second symbol character position.
Example: A Code (EAN) 128 bar code with Function 1 character in the first position,
FNC1 Aim Id is transmitted as ]C1AimId
Vista de pagina 439